SERVO DRIVE SYSTEMS
POWER DISTRIBUTION UNIT
System has its own optional AC/DC converter. It can switch at different voltages and different currents. With the control interface, on/off, status/alarm monitoring applications can be provided for each output via the upper system software. Designed according to MIL-STD-810G and MIL-STD-461 standards. Optionally, each channel can be switched on and off with mechanical switches according to user applications.
| OUTPUT CHANNELS | |
| 48VDC | 2x20A & 2x10A |
| 48VDC (optional) | 100A TBD channels |
| 28VDC | 1x40A & 1x30A 1x10A 3x5A |
| 28VDC (optional) | 100A TBD channels |
| 24VDC | 8x5A |
| 28VDC (optional) | 100A TBD channels |
| 12VDC | 5x5A |
| 5VDC | 5x5A |
| INPUT VOLTAGE | 48VDC |
| INPUT VOLTAGE (optional) | 380VAC |
| INPUT CURRENT | 300A |
| DISCRETE INPUTS (Optional) | 10x Ground / OPEN |
| DISCRETE OUTPUTS (Optional) | 10x 28VDC / OPEN (200mA per channel) |
| Protections | Overvoltage/Undervoltage/Overcurrent/Over temperature |
| COMMUNICATION | 1x Ethernet (Optional) |
| 2x CANbus (Optional) | |
| 1x RS485 | |
| 3x RS422 | |
| ENVIROMENTAL | |
| Operating Temperature | -40°C ~ 70°C |
| Storage Temperature | -40°C ~ 85°C |
| MIL-STD-810G | CONFIRMED |
| MIL-STD-461F | CONFIRMED |